Generator Size Calculator

Add up what you want to run at once, plus the extra kick for the biggest motor to start, to size a portable or standby generator.

Add the running watts of everything that will run at the same time.
Watts from nameplates.
Generator size
Peak starting load
Running load with margin
Current at 240 V / 120 V
Common appliance watts
Work

Saved Calculations

Items you add are saved in this browser.

NameCalculationResultRemove

How to Size a Generator

Peak load = total running watts − largest motor’s running watts + its starting watts
Generator running rating ≥ running watts × (1 + margin)

Only one large motor usually starts at a time, so only the biggest surge is added. Use nameplate watts; if only amps are given, watts ≈ volts × amps.

Worked Example

Tips

Standby generators connected to house wiring need a transfer switch installed per code. Never run a portable generator indoors or in a garage (carbon monoxide).